Customization: | Available |
---|---|
Application: | Power, Electronic |
Phase: | Three |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name | |||||
Industrial 3 Phase 12kv 13kv 15kv 20kv 100/250/500/1000kva Copper/Aluminum Dry Type Power Distribution Transformer Manufacturer | |||||
Product Features | |||||
Low consumption and energy-saving; Strong corrosion resistance; Low noise; Strong short-circuit resistance; Low partial discharge. |
Product Features | ||||||||||
1 | Because dry-type transformers have the advantages of strong short-circuit resistance, small maintenance workload, high operating efficiency, small size, low noise, etc., they are often used in places with high performance requirements such as fire prevention and explosion protection. Safe, fireproof, pollution-free, and can be directly used for high load power consumption. | |||||||||
2 | Adopt international advanced technology, high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability and long service life. | |||||||||
3 | Low loss, low noise, obvious energy-saving effect, maintenance-free. | |||||||||
4 | Good heat dissipation performance, strong overload capacity, and short-term over-capacity operation under forced air cooling. | |||||||||
5 | It has certain moisture-proof performance, and can operate in harsh environment with high humidity. | |||||||||
6 | The dry-type transformer can be equipped with a complete temperature detection and protection system. Intelligent signal temperature control system is adopted, which can automatically detect and patrol display the working temperature of each three-phase winding, automatically start and stop the fan, and have alarm, trip and other function settings; |
|||||||||
7 | Small size, lightweight, small floor space and low installation cost. |
Product Parameters SG(B)13,SC(B)13 Dry-type Transformer |
||||||||||
Model | Rated Capacity (kVA) |
Connections | Voltage Combination(kV) | No-load Loss (W) |
Load Loss (W) 120ºC(F) |
No-load Current (%) |
Impedance (%) |
|||
High Voltage | Tapping Range | Low Voltage | ||||||||
SC13-30 | 30 | Yyn0 or Dyn11 |
10 6.3 6 |
±5% ±2×2.5% or +3×2.5% -1×2.5% |
0.4 | 135 | 640 | 2 | 4 | |
SC13-50 | 50 | 195 | 900 | 2 | ||||||
SC13-80 | 80 | 265 | 1240 | 1.5 | ||||||
SC13-100 | 100 | 290 | 1410 | 1.5 | ||||||
SC13-125 | 125 | 340 | 1660 | 1.3 | ||||||
SC(B)13-160 | 160 | 385 | 1910 | 1.3 | ||||||
SC(B)13-200 | 200 | 445 | 2270 | 1.1 | ||||||
SC(B)13-250 | 250 | 515 | 2480 | 1.1 | ||||||
SC(B)13-315 | 315 | 635 | 3120 | 1 | ||||||
SC(B)13-400 | 400 | 705 | 3590 | 1 | ||||||
SC(B)13-500 | 500 | 835 | 4390 | 1 | ||||||
SC(B)13-630 | 630 | 965 | 5290 | 0.85 | ||||||
SC(B)13-630 | 630 | 935 | 5360 | 0.85 | 6 | |||||
SC(B)13-800 | 800 | 1090 | 6260 | 0.85 | ||||||
SC(B)13-1000 | 1000 | 1270 | 7310 | 0.85 | ||||||
SC(B)13-1250 | 1250 | 1500 | 8720 | 0.85 | ||||||
SC(B)13-1600 | 1600 | 1760 | 10500 | 0.85 | ||||||
SC(B)13-2000 | 2000 | 2190 | 13000 | 0.7 | ||||||
SC(B)13-2500 | 2500 | 2590 | 15400 | 0.7 |