Customization: | Available |
---|---|
Warranty: | 1 Year |
Cycle Life: | 6000 Times@25c,0.5cp |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name | ||||
Non-Isolated 6000times 400VAC 100kw 215kwh 150A 50/60Hz Solar Power Energy Storage Container Lithium Battery 280Ah | ||||
Product Overview | ||||
The 100kW/215kWh liquid-cooled energy storage cabinet adopts an integrated design concept. It is an energy storage product that highly integrates battery systems, BMS, PCS, EMS, fire protection and other systems. It is flexible to deploy and has functions such as peak shaving, demand management, dynamic capacity expansion, and power demand response to meet various energy storage application needs. |
Product Parameters | ||||
Model No. | HCESS1-100-215 | |||
AC side parameters | DC side parameters | |||
Grid voltage | 400Vac | Battery type | LFP 280Ah | |
Access mode | Three-phase four-wire | Rated battery capacity (@BOL) | 215kWh @25ºC/100kW | |
Rated AC power | 100kW | DC rated voltage | 768V | |
Rated AC current | 150A | DC voltage range | 600~876V | |
Rated grid frequency | 50/60Hz | Rated charge and discharge rate | 0.5C | |
Adjustable power factor range | 1 (leading) ~ 1 (lagging) | DC maximum current | 160A | |
THDi (rated power) | <3% | |||
System Parameters | ||||
Isolation method | Non-isolated | Maximum charge and discharge efficiency | ≥87% | |
Dimensions (width*height*depth) | 1350*2200*1300mm | Discharge depth | ≤90%DOD | |
Weight | approx. 2500kg | Battery temperature control method | Liquid cooling and heating | |
Operating temperature | -20ºC~50ºC | Noise | ≤75dB | |
System life | 6000 times@25ºC,0.5CP, | IP protection level | IP54 | |
Altitude | Below 2000m (Derating is required if exceeding) |
Fire protection system | Perfluorohexanone fire protection + Gas/smoke/temperature detection |
Product Features | Safe and reliable | The 100kW/215kWh liquid-cooled energy storage cabinet uses high-quality, long-life lithium iron phosphate batteries (LFP), equipped with an advanced battery management system (BMS), and has multi-level active warning and active protection functions. Multiple electrical protections are designed to quickly cut off battery-side and grid-side faults; a fire extinguishing system is deployed to ensure safe and stable operation of the system and to assist the system in self-power supply. | |||
Flexible expansion | Highly integrated and modular architecture, meeting on-demand deployment, flexible expansion, rapid construction, strong scene adaptability, and maximizing space utilization. | ||||
Easy to maintain | The modular battery module design enables single-sided maintenance; built-in intelligent local monitoring can accurately locate equipment failure points, saving time and effort, and simplifying operation and maintenance. | ||||
Technical Features | Intelligent constant temperature control of the battery, high protection structure design, meet the requirements of outdoor use; support grid-connected operation mode; have independent active and reactive power regulation, low voltage ride-through function (grid-connected); complete fault and operation log records. | ||||
Application Scenario | Basic model: single energy storage cabinet connected to the grid; | ||||
Multiple energy storage cabinets connected to the grid - optional, additional accessories and software are required (maximum 8 units can be connected in parallel); | |||||
Single off-grid cabinet - optional, additional accessories and software are required; | |||||
Multiple off-grid cabinets - optional, additional accessories and software are required (energy storage cabinet output power is less than 200kW); | |||||
Grid dispatching function - if grid dispatching is required, the software version needs to be configured; | |||||
If reverse flow protection and transformer power protection are required, a transformer and an electric meter need to be installed on the low-voltage side of the transformer (400V transformer). |